Here are the error codes for Ac sharp and the cause of the problem:
ERROR CODE | The Cause |
EE | Keys locked |
E0 | Faulty water pump |
E1 | Compressor pressure too high |
E2 | The compressor freezes in the room |
E3 | Low pressure compressor |
E4 | The compressor takes in hot air |
E5 | Compressor overload protection |
E6 | Transmit malfunction |
E8 | Check Indoor fan protection |
E9 | Check Water flow protection |
FF | Failure of connected control communication |
F0 | Faulty indoor sensor on air return vent |
F1 | Evaporator sensor malfunction |
F2 | Faulty condenser sensor |
F3 | External environment sensor malfunction |
F4 | Air release sensor malfunction |
F5 | Faulty environmental sensor on the displayer |
Update Error Codes SHARP AIR Conditioiner
Kode Error | Penyebab |
H3 | Compressor overload. |
H4 | Excess temperature of the evaporator or condenser. |
H6 | Damage to the compressor fan |
U7 | There is damage to the 4-way valve (4-way valve) |
P6 | There is a communication breakdown on the main control and drive |
PH | Overvoltage on the DC busbar |
P8 | Excess temperature on IPM or PFC |
Pc | There is a problem with the current sensor circuit |
P7 | There is a problem with the IPM or PFC temperature sensor |
P5 | Current problems with the compressor |
PL | Low current voltage |
Lc | Process failure in compressor |
P0 | Reset Drive Module |
H7 | Desynchronous compressor motor |
Ld | Missing phase |
PU | There is a problem with the charging circuit |
H6 | There is a Fan Problem |
PP | Voltage abnormalities |
ee (09-42k) | Drive chip problem |
Troubleshooting Common Sharp Air Conditioners
PROBLEM | SYMPTOMS | SOLUTIONS |
AC cannot turn on | 1. when you restart the unit | 1. Wait 3 minutes before operating the air conditioner. |
2. when turned on | 2. Wait a minute | |
Mist Out On Air Conditioner | when cooling down | The room air cools quickly and becomes foggy |
Hot outdoor unit | after the unit is stopped | The compressor radiates heat to prepare to restart |
Noise | 1. Buzz is heard when starting | 1. It's the start sound of the thermostat |
2. The sound of running water can be heard while the AC is on | and will shrink after a few minutes | |
3. The sound "shuh" is heard when the air conditioner starts / stops operation. 4. The low "shah" sound is continuously heard for | 2. This is caused by refrigerant flowing inside the unit | |
cooling operation or stop. | 3. This is the noise caused by the refrigerant | |
5. Cracking sounds can be heard during or after | stops flowing 4. Noise is heard when the drainage pump is in operation | |
AC On. | 5. This sound is produced by | |
front panel friction and more | ||
components expanding or connecting | ||
due to temperature changes | ||
Dust from the unit | Starts operating after a long period of non-use of the AC. | Dust absorbed by the air conditioner |
Smell | During operation | The smell of the room / room mixed with the air conditioner. |